FAQ : Maintenance & Safety

Release Time:2025.03.31 Browse:9

Q: What routine maintenance is required?
A:

  • Daily: Check for oil leaks; drain condensate.

  • Monthly: Clean/replace air intake filters (test per ISO 8573-1).

  • Annually: Replace dryer desiccant; pressure test tank (ASME Section VIII standards).

Q: What should I do if the compressor overheats or makes unusual noises?
A:

  1. Immediately shut down the unit.

  2. Check for:

    • Blocked ventilation (clear obstructions)

    • Low oil levels (refill with ISO VG 68 oil)

    • Loose fittings (tighten with torque wrench)
      Contact support if issues persist.